4140 流量计

TSI 4140 型流量计(0.01-20L/min 空气、O2、N2 1/4" 导管) 可用于众多气体流量监测应用领域。无论是在实验室还是生产环境监测气体流动,TSI 通用型流量计都可提供包括多种数据输出选项的精确监测结果。显示版本包括各种组件,使设置和操作快捷方便。

TSI 流量计规定为 2% 的流量读数误差。一台 TSI 流量计的量程与三台或或更多"误差为全量程的百分比的设备"...... 相比具有更好的精度。快速四毫秒响应时间确保有波动流中的测量精确性。TSI 流量计的这种快速响应时间特别适于闭环控制系统和综合体积流量监测。TSI 流量计的低压降最大程度地减小了流动回路背压及其对系统的影响。

 

应用范围

医疗领域

工业领域

实验室

特点与优势

快速且精确

低压降

技术参数


LowFlow - 4140 series

HighFlow-4040 series

Model

41401

4140

41403

4143

41433

40401

4040

4043

4045

Gas   Calibration

Air

Air.ON

irozN

Air,ON

ir,0zN

Air

Air.O.N,Air/OMixture

lnlet/Outlet   Diameter

0.25"(6.4mm)

0.375"(9.53 mm)

22mm   ISO tapered

0.50"
  (12.7 mm)

0.75"
  (19.1mm)

Measurement

Range

0.01-20 Std L/min

0-300Std L/min

0-200   std
L/min

0-300Std L/min

Accuracy   - Air oro;

±2% of reading or 0.005 Std L/min,Whichever is greater

±2% of reading or 0.005 Std L/min,Whichever is greater

Accuracy-N2

±3% of reading or 0.010 Std L/min,whichever is greater

±3% of reading or 0.010 Std L/min,whichever is greater

Accuracy-   Air/02
  mixtuire

N/A

N/A

±3% of reading or 0.1 Std L/min,whichever is greater

Accuracy-N2O

N/A

N/A

±3% of
reading
or 0.010
Std L/min,
whichever
is greater

N/A

±3% of
reading
or 0.010
Std L/min,
whichever
is greater

N/A

Response

4 ms to 63% of full scale flow

4 ms to 63% of full scale flow

LCD   Display Units

L/min,Std L/min,cm3/min,Std cm3/min

L/min,Std L/min

Overall   Dimensions

5"X2"X1.25"(127mmX49mmX32mm)

7.2"X2.5"X2.1"(182X63X53mm)

Volume*
  Measurement

Range

0.01- 999 liters

0.01- 999 liters

Accuracy

±2% of  reading (see Operator'sManual for additional details)

±2% of reading (see Operator's Manual for additional details)

Measurement

Range

50-199kPa   atsolute

50-199kPa   absolute

Accuracy

±1kPa

±1kPa

Response

<4ms to63% of final value for stepcharge

<4ms to 63% of finalvalue for step charga

Temperature
  Measurement

Range

0-50℃

0-50℃

Accuracy

±1℃ at flow greater than 1 Std L/min

±1℃ at flow greater than 1 Std L/min

Response

<75 ms to 63% of final value for step change

<75 ms to 63% of final value for step change

outputs

Analog

0-10 VDC flow only,zero and span adjustable via RS232

0-10 VDC flow only,zero and span adjustable via RS232

Digital

PS232

RS232

DCPower   input

7.5 VDC ±1.5V,300 mA max

7.5 VDC ±1.5V,300 mA max

Mounting   Threads

6-32,0.25"(6mm)

8-32,0.25"   (6mm)