性能特点:
多个测试功能于一体!
显示屏:3.5英寸点阵彩色液晶屏.
ATT:免跳闸技术(2和3线)对所有RCD无跳闸环路L PE测试.
只有2线,在没有中性线(即三相电机线)的情况下非常有用.
回路电阻测试:
高测试电流范围为2Ω,分辨率为0.001Ω.
Zs极限将电气设备标准所需的值与测量结果进行比较.
RCD测试:RCD型AC(交流电流),RCD型A(脉动直流电流),F,B(普通和选择), EV和可变RCDs.
单次和自动测试、斜坡测试和接触电压.
接地测试:所含附件可测试2项和3项接地电阻.
绝缘测试:电阻试验100, 250, 500和1000伏自动放电电压.
导通测试:200mA或15mA导通测试可选择蜂鸣快速判断.
相位测试:可检测三相系统的相位旋转,并将顺序清晰显示.
电压测试:2-600V电压测量,电源频率.
HELP:显示屏显示如何根据所选功能连接仪器.
SPD:浪涌保护器试验,用于使用变阻器的电涌保护器.
PAT:便携式电器测试仪功能,用于绝缘和保护导体电阻测试
蓝牙:"KEW CONNECT"通讯
设计符合IEC 61010-1 CAT IV 300 V, CAT III 600 V. IEC 61557-1,2,3,4,5,6,7,10
产品规格
绝缘电阻 | SPD(压敏电压) | ||||
测试电压 | 100V | 250V | 500V | 1000V | Max.1000V |
测量范围 | 2.000/20.00/200.0MΩ | 20.00/200.0/1000MΩ | 20.00/200.0/2000MΩ | 0-1000V | |
精确度 | ±2%rdg±6dgt | ±2%rdg±6dgt | ±2%rdg±6dgt | ±5%rdg±5dgt | |
额定电流 | 1.0-1.2mA | 1.0-1.2mA | 1.0-1.2mA | 1.0-1.2mA | ‐ |
短路电流 | 最大1.5mA | ‐ |
回路阻抗 | ||||||||||||
功能 | LOOP ATT | LOOP HIGH | ||||||||||
L-PE/L-N | L-PE(2线) | L-PE | L-PE | L-N/L-L | ||||||||
额定电压 | 100-260V | 48-260V | 48-260V | 100-260V | 48-500V | |||||||
测量范围 | 20.00/200.0/2000Ω | 20.00/200.0/ | 2.000Ω | 20.00Ω | ||||||||
精确度 | ±3%rdg±6dgt | ±3%rdg±10dgt | ±3%rdg±4dgt | ±3%rdg±25mΩ | ±3%rdg±4dgt | |||||||
0Ω外部回路额定测试电流: | L-N:6A/60ms | L-PE:15mA | 20Ω: | 25A/20ms | 6A/20ms | |||||||
PSC/PFC | ||||||||||||
范围 | 2000A/20kA | 2000A/20kA | 2000A/20kA | 2000A/50kA | 2000A/20kA | |||||||
精确度 | PSC/PFC 精度来自于测量的回路阻抗规范和测量的电压规范 |
RCD | ||||||||
额定电压 | 100-260V(50/60Hz) | |||||||
功能 | x1/2, x1,x5,Ramp,自动,Uc | |||||||
6/10/30/100/300/500/1000mA/变量 | ||||||||
RCD型 | AC(G/S) | A(G/S) | F(G/S) | B(G/S) | EV | |||
跳脱电流设置 | x1/2, | 10/30/100/300/ | 10/30/100/ | 10/30/100/ | 10/30/100/ | 6mA(x1仅) | ||
x5 | 10/30/100mA | 10/30/100mA | 10/30/100mA | 10/30mA | - | |||
Ramp | 10/30/100/ | 10/30/100/ | 10/30/100/ | 10/30/100/ | 6mA | |||
精确度 | ||||||||
跳脱电流 | x1/2 | -8% - -2% | -10% - 0% | -10% - 0% | -10% - 0% | - | ||
x1 | +2% - +8% | 0% - +10% | 0% - +10% | 0% - +10% | 0% - +10% | |||
x5 | +2% - +8% | 0% - +10% | 0% - +10% | 0% - +10% | - | |||
Ramp | -4% - +4% | -10% - +10% | -10% - +10% | -10% - +10% | -10% - +10% | |||
跳脱时间 | x1/2 | 2000ms(G/S):±1%rdg±2ms | - | |||||
x1 | 550ms(G):±1%rdg±2ms,1000ms(S):±1%rdg±2ms | 10.5s:±1%±2㎳ | ||||||
x5 | 410ms(G/S):±1%rdg±2ms | - | ||||||
导通测试 | ||||||||
范围 | 20.00/200.0/2000Ω (自动量程) | |||||||
开路电压(DC) | 7-14V | |||||||
测量电流 | 200mA | >200mA or more(小于2Ω) | ||||||
15mA | 15mA±3mA(短路) | |||||||
精确度 | ±2%rdg±8dgt |
电压测试 | ||
范围 | 300.0/600V(自动量程) | |
测量范围 | 电压 | 2-600V |
频率 | 45-65Hz | |
精确度 | 电压 | ±2%rdg±4dgt |
频率 | ±0.5%rdg±2dgt | |
相位旋转 | ||
额定电压 | 48-600V(50/60Hz) | |
标志 | 正确相序: 显示“1.2.3”和标志 |
接地测试 | ||||||
范围 | 20.00/200.0/2000Ω(自动量程) | |||||
精确度 | ±2%rdg±0.08Ω(20.00Ω) | |||||
安全标准 | IEC 61010-1 CAT IV 300V ,CAT III 600 V 污染度 2 | |||||
电源 | LR6 (AA) (1.5V) ×8 | |||||
通讯接口 | USB, Bluetooth®5.0,Android™5.0 以上, iOS 10.0以上 ※1 | |||||
尺寸 / 重量 | 136(L) × 235(W) × 114(D) mm / 约. 1300g (含电池) | |||||
附件 | 测试线※2 | |||||
可选件 | 8212-USB(USB适配器 "KEW Report(软件)'') |