PG 5-4500 大电流脉冲发生器设计用于电气元件、过电压保护器和电子电路的脉冲电流测试,符合 IEC、VDE 等标准。
技术参数
Technical specification | PG 5-4500 |
Mainframe control unit: | |
Microprocessor controlled touch panel | 5”, 800X480, 24 bit |
Optical Ethernet Interface for remote control of the generator | optional |
Interface for saving reports | USB |
External Trigger input | Switch |
External Trigger output | 10 V at 1 k |
Connector for external safety interlock loop | 24 V = |
external red and green warning lamps acc. to VDE 0104 | 230 V, 60W |
HV unit: | |
Charging voltage, adjustable | 0.2 - 5 kV ± 2 % |
Accuracy of the test current | < 2% |
Energy storage capacitor, selectable | 4 * 100 µF |
Charging time, max. | < 60 sec |
max. repetition rate | 1/100 sec |
Connection for ground rod | M 6 |
Ground rod | 0.7 m long |
Mains power | 230 V, 50/60 Hz, 1250 VA |
Pulse forming network | 250 A, 1.5/5000 µs |
Waveform of short circuit output current | 1.5 / 5000µs ±20% |
Peak output current, adjustable by preset of charging voltage | 2 * 5 - 125 A ± 5 % |
Polarity of pulse output current, selectable | POS/NEG |
Energy switchable 100 – 400F | 3 steps |
Monitor output for pulse output current, built-in | 100 m, 1.0 MHz |
Pulse current output: plug-in terminals on the rear panel | HV Plug |
Dimensions W * H * D | 600*800*800 mm3 |
Weight | 270 kg |
Option: | |
Test chamber on top, build in 19” rack, with security glass door, safety interlock protects the high-voltage output terminals. Upon opening of the door or switching-off of the generator, the HV output switches off. Test space ca. W*H*D |
470*530*490 mm³ |