402 系列 高压电源
行业标准的机架式电容器充电和直流电源,电容器充电的额定值为 4kJ/sec,连续直流应用中的额定值为 4kW。
额定功率为4kJ/sec,5kJ/sec峰值
输出电压从0-1kV到0-50kV
紧凑型风冷机架安装套件
基于IGBT的高效谐振逆变器
出色的脉冲间可重复性
208 或 400VAC 3Ø 输入电压
全面的远程控制界面
UL 认证的交流线路接触器(OEM 型号可选)
超可靠和坚固的行业标准设计
被动 PFC (pf = 0.85)
全本地输出电压和高压开/关控制(L 版本)
简单的并联操作,可实现更高的功率
实验室、从站或 OEM 前面板选项
技术参数
型号 | 402 系列 |
Average Capacitor Charging Power | 4,000 Joules/sec (½CV2 x Rep Rate) |
Peak Capacitor Charging Power | 5,000 Joules/sec (½CV2 ∕ tcharge) |
Average Continuous DC Power | 4,000 Watts |
Output Voltage Range | 1, 2, 4, 5, 10, 15, 20, 30, 40, 50kV, variable from 10-100% of rated |
Polarity | Available as fixed Positive or Negative. Please specify at time of ordering |
HV Output Cable | 1-39kV Models - DS2124 Coaxial cable with proprietary HV connector |
40-50kV Models - DS2214 Coaxial cable with proprietary HV connector | |
HV Insulating Medium | Shell Diala S2 or equivalent insulating oil |
AC Input Voltage | 208VAC (180-264), 3Ø - Suffix 3P208 or 400VAC (340-460), 3Ø + N - Suffix 3P400. Specify at time of ordering |
AC Input Current | 20A/15A |
AC Connector | UL/CSA approved terminal block. 3Ø + for 208VAC, 3Ø + N + for 400VAC |
AC Line Contactor | UL/CSA approved AC line contactor (standard on 402L and 402S, option for 402OEM) |
Power Factor | Passive PFC pf = 0.85 at full load and nominal AC line |
Efficiency | Better than 85% at full load |
Front Panel | 402L - Voltage Control, Voltage & Current Meters, Status Indicators |
402S - On/Off Switch, Status Indicators | |
402-OEM - Blank front panel | |
Stability | 0.2% per hour after 1 hour warmup |
Temperature Coefficient | 100ppm per °C typical |
Stored Energy | Less than 0.3J all models |
Pulse to Pulse Repeatability | ±2% to 1000Hz, consult factory for higher rep rates |
Dimensions - inches (mm) | 19 (483) W x 7 (178) H x 17 (432) D |
Weight - lbs (kg) | 65 (30) |
Ambient Temperature | Storage: -40 to +85°C. Operating: -20 to +45°C |
Altitude | Storage: 40,000ft (12,000m), Operating: 9,900ft (3,000m) |
Humidity | 10-90%, non-condensing |
Protection | Open/short circuits, Overloads, Arcs, Overtemp, Overvoltage, Safety Interlock |
Remote Control (all models) | Via 25-pin D-sub connector on rear of unit, Signals include, |
Accessories | 10ft HV cable, operating manual |
Options | EN - Low Enable. Replaces standard high enable |
5V - 0-5V Analog programming. Replaces standard 0-10V programming. | |
LP - Latching Overload Protection, requires HV reset after overload fault | |
DC - Continuous DC operation | |
CT - AC line contactor (option for 402OEM models only, standard on 402L and 402S) | |
Double terminated HV cable, and mating bulkhead connector | |
Ordering Info | Model - XXkV - POS (or NEG) - 3PYYY - ZZ (options) |
Ordering Examples | 402L-10kV-POS-3P208, 402S-1kV-NEG-DC-3P208, 402-OEM-50kV-POS-3P400 |
All specifications subject to change without notice |
产品尺寸