特点
1、适合小型工件的2面不平衡测试;
2、可对应0.001kg~30kg的工件;
3、精度高、误差少。
技术参数
形式Model | SG8-003NⅡ | SGB-03NⅡ | SGB-1NⅢ | SGB-3NⅡ | SGB-10NⅡ | SGB-30NⅡ |
STB-003NⅢ | STB-03NⅢ | STB-1NⅡ | ST8-3NⅢ | STB-10NⅡ | ST8-30NⅢ | |
试验体重量 Work piece weight(kg) | 0.001 to 0.03 | 0.01 to 0.3 | 0.01 to 1 | 0.03 to 3 | 0.1 to 10 | 0.3 to 30 |
试验体最大直径 Max. work piece diameter(mm) | 30 | 60 | 200 | 300 | ||
皮带架最大躯身径 Max.diameter for belt drive(mm) | 30 | 40 | 150 | |||
轴承间距离 Span across bearings(mm) | 15 to 185 | 50 to 370 | 60 to 520 | |||
试验体轴径⑴ Work piece shaft diameter(1) (mm) | 1.5 to6 | 1.5 to8 | 5 to 15 | 5 to 25 | 10 to40 | |
驱动电机 Drive motor(W) | 18 (步进电机 Stepping motor) | 90(可变速 Varioble speed) | 200(可变速 Variable speed) | |||
轴承方式⑴) Bearing type (1) | V形轴承(1种) Bearing(1 set) | 滚轮轴承(1种) Roller bearing (1 set) | ||||
到达最小比不平衡(2) Min.achievable residual unbalance (2) (μm) | 0.1(对于最大试验体重量的偏重心距离 Mass eccentricity for a work piece of max.weight) | |||||
每面到达最小不平衡 Min.achievableubalance on one.plane(g·mm) | 0.0008 | 0.003 | 0.01 | 0.03 | 0.1 | 0.3 |
试验速度⑶ testing speed (3) (rpm) | 700 to 3600(依据试验体外径尺寸等Depending on outer diameter of work piece) | |||||
皮带驱动方式(4) Belt drive system( 4) | 下方切线以及缠绕驱动 Dowrward-tangential and winding drive | |||||
机器本体重量 weight(kg) | 50 | 80 | 200 | |||
电源 Power supply | 单相 Single-phase 100V,10A,1 kVA | 单相 Single-phase 200V,10A,2 kVA |